How to choose suitable tubine flowmeter
This instruction manual has not yet provided descriptions in respect to different characteristics of
users. By the way, when modifying technical parameter, structure or parts of the flow meter, as long
as such modifications cause no impacts on functions and operation of the flow meter, this instruction
manual will not be revised accordingly each time.
Explanation of Model and Suffix Code | ||||||
Table for Model & Specification Codes of LWGY Turbine Flow meter Table 2 | ||||||
Model | Specification code | Note: | ||||
LW----------------------------------------------------- | Turbine type flow instrument | |||||
G ------------------------------------------------------- | Flow meter | |||||
Y--------------------------------------------------------- | Liquid | |||||
Nominal diameter | 2 | 2mm(pipe thread G1/4") | ||||
3 | 3mm(pipe thread G1/4") | |||||
4 | 4mm(pipe thread G1/4") | |||||
6 | 6mm(pipe thread G3/8”, wafer type, flange type,and quick release type) | |||||
10 | 10mm(pipe thread G1/2”, wafer type, flange type and quick release type) | |||||
15 | 15mm(pipe thread G1”, wafer type, flange type and quick release type) | |||||
20 | 20mm(pipe thread G1”, wafer type, flange typeand quick release type) | |||||
25 | 25mm (pipe thread G1 1/4”, wafer type, flange type and quick release type) | |||||
32 | 32mm (pipe thread G1 1/2”, wafer type, flange type and quick release type) | |||||
40 | 40mm (flange type, quick release type) | |||||
50 | 50mm (flange type, quick release type) | |||||
65 | 65mm (flange type, quick release type) | |||||
80 | 80mm (flange type, quick release type) | |||||
100 | 100mm (flange type, quick release type) | |||||
150 | 150mm (flange type) | |||||
200 | 7.87in (flange type) | |||||
250 | 9.84in (flange type) | |||||
300 | 300mm (flange type) | |||||
Integrated type | M | Symbol for a flow meter integrating with a converter | ||||
Structure No. of flow | A ------------------------------- | Common type | ||||
meter | B | -------------------------- | Wearing resistant type | |||
C | -------------------------- | Anti-corrosive type | ||||
Accuracy grade | A | ------------------- | Intrinsic error limit ±1.0% | |||
B | ------------------- | Intrinsic error limit ±0.5% | ||||
C | ------------------- | Intrinsic error limit ±0.2% | ||||
Connecting patterns* | G | Pipe thread type of non thread sealing | ||||
R | Pipe thread type of thread sealing | |||||
F | Flange connection type | |||||
J | wafer type | |||||
K | Quick release connection | |||||
Nominal pressure | S1 | ----------------- | PN1.6Mpa | |||
S2 | ----------------- | PN2.5Mpa | ||||
S3 | ----------------- | PN4.0Mpa | ||||
S4 | ----------------- | PN6.3Mpa | ||||
S5 | ----------------- | PN16Mpa(DN≤50mm) | ||||
S6 | ----------------- | PN25Mpa(DN≤50mm) | ||||
S7 | ----------------- | PN40Mpa(DN≤50mm) |